The importance of mechanical circulatory support on pediatric waitlist and post heart transplant survival: a narrative review
Review Article

The importance of mechanical circulatory support on pediatric waitlist and post heart transplant survival: a narrative review

David W. Bearl^

Monroe Carell Jr. Children’s Hospital at Vanderbilt, Nashville, Tennessee, USA

^ORCID: 0000-0002-1325-4814.

Correspondence to: David W. Bearl. 2200 Children’s Way, Doctor’s Office Tower Suite 5230, Nashville, TN, 37232, USA. Email: david.w.bearl@vanderbilt.edu.

Background and Objective: While heart transplantation for children with end-stage heart failure has been available for more than 50 years, outcomes on the waitlist and as well as post-transplant outcomes have not always been favorable. Post-transplant survival initially showed marked improvement with better and better immunosuppression regimens. However, waitlist outcomes (as well as those deemed too sick to list) remained unfortunately low. With the introduction of mechanical circulatory support (MCS) in the 1970s, a new hope for the those with end-stage heart failure emerged. This paper will review the past, present and what is on the horizon for MCS as a bridge to heart transplantation in pediatric patients.

Methods: A search of peer-reviewed scientific studies published in English from 1990−2020 using the PubMed database with keywords including extracorporeal membrane oxygenation (ECMO), ventricular assist devices (VAD) and heart transplantation all focusing on pediatrics.

Key Content and Findings: Initially ECMO and intra-aortic balloon pumps were tried but both waitlist and post-transplant mortality were unacceptable. Paracorporeal pulsatile VAD ushered in better waitlist survival and intracorporeal continuous-flow VAD borrowed from the adults have increased safety both before and after transplant. Over the last couple of decades that hope of MCS has turned into remarkable advances in pre- and post-transplant outcomes.

Conclusions: As survival continues to improve, there is now a push to decrease morbidity seen in many of the early devices. Even the current devices available continue to exhibit unreasonably high complication rates, especially in the smaller and more complex patients.

Keywords: Pediatrics; mechanical circulatory support (MCS); ventricular assist device (VAD); heart transplantation


Received: 31 January 2021; Accepted: 25 June 2021; Published: 28 August 2022.

doi: 10.21037/pm-21-10


Introduction

Since the first adult heart transplant (1) and pediatric heart transplant (2) both in 1967, the need for pre-operative management of end-stage heart failure has been apparent. The first decade saw patients transplanted only from geographical and temporal luck—the patient was in need and stable enough, while the donor organ became available nearby. However, this strategy significantly limited recipients’ ability to get a donor heart. Therefore, ways to bridge patients with end-stage heart failure for longer periods of time were necessary and have continued to evolve. This narrative review will cover the history and the current options for mechanical circulatory support (MCS) as a bridge to transplant, as well as the impact on post-transplant survival. The following article is presented in accordance with the Narrative Review reporting checklist (available at https://pm.amegroups.com/article/view/10.21037/pm-21-10/rc).


Methods

A search of peer-reviewed scientific studies published in English from 19902020 was performed using the PubMed database (see details in Table 1). Keywords included pediatric MCS, pediatric extracorporeal membrane oxygenation (ECMO), pediatric ventricular assist devices (VAD), and pediatric heart transplantation. Reference lists of selected papers were also reviewed to identify relevant studies pertaining to this subject. Relevant articles including case reports, case series, cohort studies, registry reports, and prospective trials were included in this narrative review.

Table 1

The search strategy summary

Items Specification
Date of search January 20th, 2021
Databases and other sources searched PubMed
Search terms used Pediatric, mechanical circulatory support (MCS), extracorporeal membrane oxygenation (ECMO), ventricular assist device (VAD), heart transplantation
Timeframe 1990–2020
Inclusion and exclusion criteria Inclusion criteria: all studies including case reports, case series, cohort studies, registry reports and prospective trials; exclusion criteria: non-English studies
Selection process Citation selection was performed by the author

Historical background

ECMO

ECMO, or historically referred to as veno-arterial cardiopulmonary bypass, was first used as a bridge to transplant in early 1980s (3). It became the initial standard of care for infants and children in need of mechanical support as a bridge to transplant. However, reviews continue to show poor outcomes as a bridge to transplant both on the waitlist and post-transplant (4,5).

Intra-aortic balloon pumps

Following some of the success in the adult MCS world, attempts at using intra-aortic balloon pumps as a means of MCS were also employed in the 1980s and 1990s (6,7). However, overall success was limited because of difficulty in placing in small vessels, in synchronizing the device with the faster pediatric heart rates, and in providing sufficient cardiac output support.

The first VAD

The VAD implanted in a pediatric patient was an adult device called the DeBakey VAD (MicroMed Technology, Houston, TX, USA) in a 6-year-old in 1967, although the indication was for cardiac recovery (8). Attempts to use adult-sized devices, both pulsatile and non-pulsatile, continued throughout the 1970s and into the 1980s (9). The next big step forward was in 1989, this time in Germany, where an adult-sized (50 mL) Berlin Heart EXCOR (Berlin Heart GmbH, Berlin, Germany) was implanted in an 8-year-old who survived to transplant (10). In the 1990s, the concept of pediatric-specific devices started to develop with trials in Japan (11), Germany (10), Australia (12) and the United States (13). Thoratec VAD (Thoratec Corp, Pleasanton, CA, USA), another adult-designed device, was one of the first more widely used in pediatrics in the United States, although due to the size it was limited to larger adolescent patients. Early experience showed modest results with significant thromboembolic complications (14). Table 2 shows many of the VADs that are used in the pediatric population.

Table 2

Available ventricular assist devices

Device Type FDA/CE mark approval in adults (year) FDA/CE mark approval in pediatrics (year)
Berlin Heart EXCOR Paracorporeal pulsatile flow No/yes (N/A, 1996) Yes, all ages (2011/1996)
HeartWare HVAD Intracorporeal continuous flow Yes (2012/2009) No
HeartMate 3 Intracorporeal continuous flow Yes (2017/2015) Yes (2020/2015)
SynCardia Total Artificial Heart Intracorporeal pulsatile flow Yes (2004/1999) Yes, if adequate size (2020/1999)
Jarvik 2015 Intracorporeal continuous flow No No
HeartAssist 5 Intracorporeal continuous flow No Yes, 5–16 years (BSA 0.7–1.5 m2) (2004/2001)
Centrimag/Pedimag Paracorporeal continuous flow Yes, Centrimag* (2009/2002) No
Rotaflow Paracorporeal continuous flow No No
Impella Percutaneous continuous flow Yes** (2015/2012) RP only, BSA >1.5 m2** (2018/2014)
TandemHeart Percutaneous continuous flow No No

*, up to 30 days of support; **, up to 4 days for 2.5 and CP sizes, and 14 days for RP, 5.0, LD and 5.5 sizes.


Berlin Heart: the game changer

In Germany in 1991, Berlin Heart used the EXCOR design of a pneumatic, pulsatile, paracorporeal pump into smaller pediatric-appropriate sizes. Other devices were designed and tested around that time (15), but were largely abandoned due to the comparative success of the Berlin Heart EXCOR. Hetzer et al. report the first European series of patients on the original Berlin Heart, and showed remarkable success for the time (16). The device received European marketing approval in 1996, with Canada (2009) and the United States (2011) following later. The design includes pumps of 10, 15, 25, 30, 50 and 60 mL in size. The growth of its use expanded significantly through the first decade of the 21st century, increasing from 1–4 implants per year in the US from 2000–2004 to more than 80 by the end of the decade (17).

Early experience

European and North American trials showed improved outcomes compared to ECMO for pediatric patients bridged with Berlin Heart as well as post-transplant outcomes approaching those transplanted on inotropic support (18,19). Initial North American data regarding compassionate use in 73 patients showed 70% were able to be bridged to transplant with younger age and biventricular support identified as risk factors for death (20). A single center in Germany showed that of 122 cases, 46% were bridged to transplant while another nearly 15% were explanted after myocardial recovery (21). In the second half of the 2000s, use of the Berlin Heart increased dramatically, and with it, the complexity of cases increased as well. From 2007–2010, 204 devices were implanted in North America, with 2/3 under compassionate use (17). The compassionate use group was smaller, enrolled many more patients with congenital heart disease including 19 with single ventricle physiology [none in the Investigational Device Exemption (IDE) group] and were more likely to be on ECMO prior to cannulation. Not surprisingly, compared with IDE subjects, children implanted under compassionate use were less likely to survive to transplant (53% vs. 85%, P<0.01) and were more likely to die (34% vs. 7%; P<0.01). Also important from this study was that the stroke rate, a known dreaded complication, remained high at 29%, despite the increasing complexity of the patient population. However, in a separate analysis, those patients who survived to transplant on a Berlin Heart had similar post-transplant 1-year survival to those transplanted as similar priority status patients without VAD (88.7% vs. 89.3%, P=0.005) (22).

Current outcomes

In the last decade, both morbidity and mortality continue to decrease. In a multicenter North American trial, 21 patients were supported on Berlin Heart EXCOR with a direct thrombin inhibitor (bivalirudin or argatroban) as the primary anticoagulant, as opposed to heparin, and had 90% survival to transplant (23). Using that knowledge, the Advanced Cardiac Therapies Improving Outcomes Network (ACTION), implemented a quality improvement initiative that dropped the stroke rate on device down to 12% (24). Another major issue for the Berlin Heart has been the increased risk of morbidity and mortality for the smallest patients. That too, continues to improve with better survival and fewer strokes for patients younger than 1 year or <10 kg, although still not as favorable as older or larger children (25,26). Major challenges still remain, though, as outcomes for patients with single ventricle physiology continue to be overall poor (27). The FDA post-approval surveillance study report published this year shows how far the field has come. Despite significantly more risk factors such as being younger, smaller, and more likely to have congenital heart disease, the post-marketing approval surveillance study group had an 86% 6-month success rate (transplant, explant with recovery or still on device) compared to 76% for previously reported Berlin Heart study group (28). All adverse events improved including stroke (11.5 vs. 3.99 events per 100 patient months), major bleeding (33.9 vs. 6 events per 100 patient months), and major infection (40.36 vs. 10.39 events per 100 patient months). Frequency of pump exchanges also decreased 40%. Similarly, centers across the globe continue to show improvements in waitlist and post-transplant mortality (29-32).


Intracorporeal devices: continuing to borrow from adults

Early experiences

Early reports of intracorporeal continuous-flow device use in near-adult-sized adolescents started the wave of adapting new devices for pediatric use. The DeBakey VAD Child, now called the HeartAssist 5 (ReliantHeart, Inc., Houston TX, USA), a smaller version of the adult-sized DeBakey VAD, is an axial-flow pump that earned European approval in 2001 and US approval in 2004. The first successful use of the device as a bridge to pediatric transplant occurred a year later (33). However, due to its relatively large size and multiple reports of neurologic complications it has not been widely adopted in pediatrics (34). HeartMate II (Abbott Corporation, Abbott Park, IL, USA) is an axial flow device that helped usher in a significant improvement in VAD outcomes in adults. Experience in pediatrics was again limited due to its large size, but still showed important mortality advantages. In one of the first large case series evaluating intracorporeal devices in pediatrics, Cabrera et al. showed excellent positive outcomes with 96% either transplanted, alive on device or recovered (35). HeartWare HVAD (Medtronic, Minneapolis, MN, USA), a centrifugal continuous-flow pump, received approval in adults in the US in 2012. The first reported cases of HVAD use in pediatrics were in Europe in the early 2010s (36), with the first reported case in the US coming shortly after (37).

Current outcomes

Success in bridging pediatric patients to heart transplant with the HeartWare HVAD is now a worldwide effort. In a study by Conway et al., the authors showed overall positive results regardless of geographic location (38). Notably, need for temporary right-sided support (HR 10.65, 95% CI: 12.53–44.81, P=0.001) or pump exchange (HR 7.9, 95% CI: 1.8–34.2, P=0.006) were associated with death on device. Data from the Pediatric Interagency Registry for Mechanically Assisted Circulatory Support (Pedimacs) registry showed that overall success with HeartWare as a bridge to transplant was on par with adult outcomes (39). Six-month survival was 86.5% compared to 93% for young adults (1930 years old), which was not statistically significant. Similar results have been shown in the European Registry for Patients with Mechanical Circulatory Support Paediatric (Paedi-Euromacs) (32). With the improving success of intracorporeal devices as single left ventricular support, pediatric centers continue to push the boundaries of who can be supported. Use of intracorporeal devices for congenital heart disease, including failing single ventricle Fontan physiology, is expanding and improving (40). The earliest reports of using HVAD biventricular support (BiVAD) showed promise with 3 patients successfully bridged to transplant (41). Multicenter outcomes from intracorporeal BiVAD configuration still show success although with clearly added risk compared to LVAD-only (42). One of the newer devices gaining adoption in pediatrics is the HeartMate 3 (Abbott Corporation, Abbott Park, IL), another intracorporeal, centrifugal pump. Advantages to this device have been shown in the adult population including less stroke and less pump thrombosis (43). ACTION put together the combined experience of participating centers and demonstrated the efficacy of the HeartMate 3 in 35 children, including 17% with congenital heart disease (44). There was only one death (97% survival), and 57% were successfully bridged to transplant, while the rest remained alive on device. Importantly, there were no episodes of stroke or pump thrombosis. This work led HeartMate 3 to earn FDA-approval for pediatric patients in 2020.


Post-transplant outcomes after MCS

Early outcomes

Evaluation of post-transplant survival after bridge from ECMO showed overall poor results. In Toronto, Canada, post-transplant survival using ECMO as a bridge to transplant was only 67% and 52% at 1 and 5 years, respectively (45). A multi-center North American study from 19942009 showed even worse post-transplant survival for children bridged with ECMO with only 47% surviving to discharge (4). As VADs became more common as an MCS modality for bridge to transplant, there was early recognition of the potential post-transplant benefits. In a study mentioned earlier reviewing Berlin Heart pediatric patients bridged to transplant, 1-year survival was 87.1% (22). Early review of all VAD types in pediatrics from 1995 to 2011, showed paracorporeal VADs were associated with a higher post-transplant mortality (OR 3.0, 95% CI: 0.810.6) while other types were associated with lower post-transplant mortality (OR 0.5, 95% CI: 0.21.0) compared to no MCS (46). Evaluation of early continuous-flow devices including both HeartMate II (n=80) and HeartWare (n=58) again showed improvingly favorable post-transplant outcomes with 1-year and 5-year survival of 100% and 88%, respectively (47).

Current outcomes

As the pediatric heart transplant community gained experience, including better anticoagulation strategies and better timing for implantation, overall post-transplant outcomes have continued to improve. In a Pedimacs and Pediatric Heart Transplant Study (PHTS) linkage study, there were no differences in post-transplant outcomes including 1-year survival (96% vs. 93%), freedom from infection (81% vs. 79%) or freedom from rejection (71% vs. 74%) between those bridged with a VAD compared to those bridged without a VAD, despite having greater pre-listing illness severity (48). Most notably, the authors conclude that “VAD as a bridge to transplant mitigates severity of illness in children.” Similar post-transplant outcomes were noted in review of pediatric VAD use across the world including in Spain (49), Australia (50) and Turkey (51). Looking specifically at one of the more challenging populations to support, children with congenital heart disease showed similar 1-year (84% vs. 87%) and 5-year (72% vs. 75%) (P=0.694) post-transplant survival compared to children with congenital heart disease bridged without VAD (52). In the most recent report on pediatric heart transplantation from the International Society for Heart and Lung Transplantation (ISHLT), Kaplan-Meier estimates showed no difference in post-transplant survival between VAD or total artificial heart (TAH) vs. no MCS (P=0.982), while there was still a significant difference for ECMO vs. VAD or TAH (P=0.0062) and no MCS (P=0.0037) (53).

In regards to the most common devices, Berlin Heart EXCOR has shown similar 30-day, 1-year and 5-year post-transplant survival compared to a similar non-MCS cohort (94%, 90% and 72% vs. 98%, 91% and 77%, P=0.16) (54). Even better 5-year results (81% survival) were seen specifically in patients bridged as part of the Berlin Heart IDE trial (55). One-year survival for patients with continuous-flow devices (mostly HeartWare in this study) was 97.3% (48). Even more remarkable, no post-transplant mortality to date has been noted for pediatric patients bridged with the HeartMate 3 device, although overall numbers remain small (44).


Discussion

With waitlist mortality for pediatric patients on VAD continuing to improve and post-transplant survival equal to patients bridged without MCS, the pediatric VAD and transplant community has started to shift focus to other key areas including reducing morbidity and bridge to bridge management.

Stroke was one of the biggest causes of morbidity (and mortality) for early devices. It continues to haunt pediatric practitioners despite improvements in devices, patient selection and management. While single-center studies and small case series have been helpful to introduce novel management strategies and surgical techniques, the small number of patients are insufficient to create evidence-based recommendations. Because individual centers all have relatively few pediatric patients, registries such as Pedimacs and Euromacs have created larger data repositories that have helped further define complications and morbidities with pediatric VAD use including stroke rate, infection, bleeding, and inpatient length of stay. The latest effort to advance the field further and faster is through a learning network that has both elements of data registry and quality improvement. ACTION is leading this charge now with more than 50 sites across the world under the motto “steal shamelessly and share seamlessly” (56). As mentioned earlier, through this network there have been significant inroads in stroke reduction for paracorporeal pumps and regulatory approval for devices in pediatrics. Ongoing work continues to push current devices such as SynCardia Total Artificial Heart (SynCardia Systems Inc, Tucson, AZ, USA) (57) and new devices such as the Jarvik 2015 (Jarvik Inc, New York, NY, USA) (58) to better support children as a bridge to heart transplant.

Bridge to bridge management is the idea that before a patient is deemed stable enough for a durable VAD such as a Berlin Heart, HeartWare or HeartMate 3, that a temporizing form of mechanical support may be necessary and could potentially improve outcomes. VA-ECMO remains the gold-standard for temporizing MCS in pediatric patients with cardiogenic shock in part because of the ease and rapidity of deployment as well as full cardiopulmonary support. Other temporary paracorporeal devices that are implanted surgically include Rotaflow (Maquet, Rastatt, Germany) and Pedimag/Centrimag (Abbott Laboratories, Abbott Park, IL, USA). These devices can be placed with ECMO cannulae, or have been used with Berlin Heart cannulae, thereby simplifying conversion to the EXCOR (59,60). Some centers have used these devices longer-term as a bridge to transplant as well with mixed success, although often in the setting of the sickest patients (61). Finally, more interest has been shown in recent years for percutaneous bridge to bridge options such as the TandemHeart (CardiacAssist, Pittsburgh, PA, USA) or Impella (Abiomed, Danvers, MA, USA) devices, which are via femoral or axillary artery access (62). There is limited adult data of Impella use as direct bridge to transplant in settings where waitlist times are expected to be very short (63). Ultimately, these strategies have come about due to the unacceptably high morbidity and mortality among children presenting with acute cardiogenic shock.


Conclusions

Half a century of advancements has yielded tremendous results in the field of MCS and heart transplantation. Children of all ages, sizes and anatomies are being better supported than ever before with less waitlist mortality despite increased disease severity and excellent post-transplant outcomes. However, that enthusiasm continues to be tempered by the residual morbidity of today’s devices. More work is needed to improve patient selection, management of current devices available, design of newer and safer devices, and post-transplant care.


Acknowledgments

Funding: None.


Footnote

Reporting Checklist: The author has completed the Narrative Review reporting checklist. Available at https://pm.amegroups.com/article/view/10.21037/pm-21-10/rc

Peer Review File: Available at https://pm.amegroups.com/article/view/10.21037/pm-21-10/prf

Conflicts of Interest: The author has completed the ICMJE uniform disclosure form (available at https://pm.amegroups.com/article/view/10.21037/pm-21-10/coif). The author has no conflicts of interest to declare.

Ethical Statement: The author is accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. Barnard CN. The operation. A human cardiac transplant: an interim report of a successful operation performed at Groote Schuur Hospital, Cape Town. S Afr Med J 1967;41:1271-4. [PubMed]
  2. Kantrowitz A, Haller JD, Joos H, et al. Transplantation of the heart in an infant and an adult. Am J Cardiol 1968;22:782-90. [Crossref] [PubMed]
  3. del Nido PJ, Armitage JM, Fricker FJ, et al. Extracorporeal membrane oxygenation support as a bridge to pediatric heart transplantation. Circulation 1994;90:II66-9. [PubMed]
  4. Almond CS, Singh TP, Gauvreau K, et al. Extracorporeal membrane oxygenation for bridge to heart transplantation among children in the United States: analysis of data from the Organ Procurement and Transplant Network and Extracorporeal Life Support Organization Registry. Circulation 2011;123:2975-84. [Crossref] [PubMed]
  5. Dipchand AI, Mahle WT, Tresler M, et al. Extracorporeal Membrane Oxygenation as a Bridge to Pediatric Heart Transplantation: Effect on Post-Listing and Post-Transplantation Outcomes. Circ Heart Fail 2015;8:960-9. [Crossref] [PubMed]
  6. Pennington DG, Swartz MT. Circulatory support in infants and children. Ann Thorac Surg 1993;55:233-7. [Crossref] [PubMed]
  7. Minich LL, Tani LY, Hawkins JA, et al. Intra-aortic balloon pumping in children with dilated cardiomyopathy as a bridge to transplantation. J Heart Lung Transplant 2001;20:750-4. [Crossref] [PubMed]
  8. DeBakey ME. Left ventricular bypass pump for cardiac assistance. Clinical experience. Am J Cardiol 1971;27:3-11. [Crossref] [PubMed]
  9. Ashton RC Jr, Oz MC, Michler RE, et al. Left ventricular assist device options in pediatric patients. ASAIO J 1995;41:M277-80. [Crossref] [PubMed]
  10. Warnecke H, Berdjis F, Hennig E, et al. Mechanical left ventricular support as a bridge to cardiac transplantation in childhood. Eur J Cardiothorac Surg 1991;5:330-3. [Crossref] [PubMed]
  11. Taenaka Y, Takano H, Noda H, et al. Experimental evaluation and clinical application of a pediatric ventricular assist device. ASAIO Trans 1989;35:606-8. [Crossref] [PubMed]
  12. Karl TR, Sano S, Horton S, et al. Centrifugal pump left heart assist in pediatric cardiac operations. Indication, technique, and results. J Thorac Cardiovasc Surg 1991;102:624-30. [Crossref] [PubMed]
  13. Daily BB, Pettitt TW, Sutera SP, et al. Pierce-Donachy pediatric VAD: progress in development. Ann Thorac Surg 1996;61:437-43. [Crossref] [PubMed]
  14. Reinhartz O, Keith FM, El-Banayosy A, et al. Multicenter experience with the thoratec ventricular assist device in children and adolescents. J Heart Lung Transplant 2001;20:439-48. [Crossref] [PubMed]
  15. Konertz W, Hotz H, Schneider M, et al. Clinical experience with the MEDOS HIA-VAD system in infants and children: a preliminary report. Ann Thorac Surg 1997;63:1138-44. [Crossref] [PubMed]
  16. Hetzer R, Hennig E, Schiessler A, et al. Mechanical circulatory support and heart transplantation. J Heart Lung Transplant 1992;11:S175-81. [PubMed]
  17. Almond CS, Morales DL, Blackstone EH, et al. Berlin Heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children. Circulation 2013;127:1702-11. [Crossref] [PubMed]
  18. Stiller B, Hetzer R, Weng Y, et al. Heart transplantation in children after mechanical circulatory support with pulsatile pneumatic assist device. J Heart Lung Transplant 2003;22:1201-8. [Crossref] [PubMed]
  19. Jeewa A, Manlhiot C, McCrindle BW, et al. Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation. Artif Organs 2010;34:1087-91. [Crossref] [PubMed]
  20. Morales DL, Almond CS, Jaquiss RD, et al. Bridging children of all sizes to cardiac transplantation: the initial multicenter North American experience with the Berlin Heart EXCOR ventricular assist device. J Heart Lung Transplant 2011;30:1-8. [Crossref] [PubMed]
  21. Hetzer R, Kaufmann F, Delmo Walter EM. Paediatric mechanical circulatory support with Berlin Heart EXCOR: development and outcome of a 23-year experience. Eur J Cardiothorac Surg 2016;50:203-10. [Crossref] [PubMed]
  22. Eghtesady P, Almond CS, Tjossem C, et al. Post-transplant outcomes of children bridged to transplant with the Berlin Heart EXCOR Pediatric ventricular assist device. Circulation 2013;128:S24-31. [Crossref] [PubMed]
  23. VanderPluym CJ, Cantor RS, Machado D, et al. Utilization and Outcomes of Children Treated with Direct Thrombin Inhibitors on Paracorporeal Ventricular Assist Device Support. ASAIO J 2020;66:939-45. [Crossref] [PubMed]
  24. Villa CR, VanderPluym CJ. ACTION Investigators*. ABCs of Stroke Prevention: Improving Stroke Outcomes in Children Supported With a Ventricular Assist Device in a Quality Improvement Network. Circ Cardiovasc Qual Outcomes 2020;13:e006663. [Crossref] [PubMed]
  25. Miera O, Morales DLS, Thul J, et al. Improvement of survival in low-weight children on the Berlin Heart EXCOR ventricular assist device support†. Eur J Cardiothorac Surg 2019;55:913-9. [Crossref] [PubMed]
  26. Conway J, Cantor R, Koehl D, et al. Survival After Heart Transplant Listing for Infants on Mechanical Circulatory Support. J Am Heart Assoc 2020;9:e011890. [Crossref] [PubMed]
  27. Chen S, Rosenthal DN, Murray J, et al. Bridge to Transplant with Ventricular Assist Device Support in Pediatric Patients with Single Ventricle Heart Disease. ASAIO J 2020;66:205-11. [Crossref] [PubMed]
  28. Zafar F, Conway J, Bleiweis MS, et al. Berlin Heart EXCOR and ACTION post-approval surveillance study report. J Heart Lung Transplant 2021;40:251-9. [Crossref] [PubMed]
  29. Rohde S, Antonides CFJ, Muslem R, et al. Pediatric Ventricular Assist Device Support in the Netherlands. World J Pediatr Congenit Heart Surg 2020;11:275-83. [Crossref] [PubMed]
  30. Davis LM, Lee MGY, Sheridan BJ, et al. Berlin Heart EXCOR Support in the First Year of Life: A Single Centre Experience. Heart Lung Circ 2021;30:446-53. [Crossref] [PubMed]
  31. Bhatia I, Ho KC, Rocha BA, et al. Pediatric ventricular assist device therapy for advanced heart failure-Hong Kong experience. J Artif Organs 2020;23:133-9. [Crossref] [PubMed]
  32. de By TMMH, Antonides CFJ, Schweiger M, et al. The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): second EUROMACS Paediatric (Paedi-EUROMACS) report. Eur J Cardiothorac Surg 2020;57:1038-50. [Crossref] [PubMed]
  33. Imamura M, Hale S, Johnson CE, et al. The first successful DeBakey VAD child implantation as a bridge to transplant. ASAIO J 2005;51:670-2. [Crossref] [PubMed]
  34. Vanderpluym CJ, Fynn-Thompson F, Blume ED. Ventricular assist devices in children: progress with an orphan device application. Circulation 2014;129:1530-7. [Crossref] [PubMed]
  35. Cabrera AG, Sundareswaran KS, Samayoa AX, et al. Outcomes of pediatric patients supported by the HeartMate II left ventricular assist device in the United States. J Heart Lung Transplant 2013;32:1107-13. [Crossref] [PubMed]
  36. Miera O, Potapov EV, Redlin M, et al. First experiences with the HeartWare ventricular assist system in children. Ann Thorac Surg 2011;91:1256-60. [Crossref] [PubMed]
  37. D'Alessandro D, Forest SJ, Lamour J, et al. First reported use of the heartware HVAD in the US as bridge to transplant in an adolescent. Pediatr Transplant 2012;16:E356-9. [Crossref] [PubMed]
  38. Conway J, Miera O, Adachi I, et al. Worldwide Experience of a Durable Centrifugal Flow Pump in Pediatric Patients. Semin Thorac Cardiovasc Surg 2018;30:327-35. [Crossref] [PubMed]
  39. VanderPluym CJ, Adachi I, Niebler R, et al. Outcomes of children supported with an intracorporeal continuous-flow left ventricular assist system. J Heart Lung Transplant 2019;38:385-93. [Crossref] [PubMed]
  40. Santamaria RL, Jeewa A, Cedars A, et al. Mechanical Circulatory Support in Pediatric and Adult Congenital Heart Disease. Can J Cardiol 2020;36:223-33. [Crossref] [PubMed]
  41. Stein ML, Yeh J, Reinhartz O, et al. HeartWare HVAD for Biventricular Support in Children and Adolescents: The Stanford Experience. ASAIO J 2016;62:e46-51. [Crossref] [PubMed]
  42. Schweiger M, E, Mascio C, Kanter KR, et al. Intracorporeal Biventricular Assist Devices Using the Heartware Ventricular Assist Device in Children. ASAIO J 2020;66:1031-4. [Crossref] [PubMed]
  43. Mehra MR, Naka Y, Uriel N, et al. A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure. N Engl J Med 2017;376:440-50. [Crossref] [PubMed]
  44. O'Connor MJ, Lorts A, Davies RR, et al. Early experience with the HeartMate 3 continuous-flow ventricular assist device in pediatric patients and patients with congenital heart disease: A multicenter registry analysis. J Heart Lung Transplant 2020;39:573-9. [Crossref] [PubMed]
  45. BarZiv SM. Outcomes of pediatric patients bridged to heart transplantation from extracorporeal membrane oxygenation support. ASAIO J 2007;53:97-102. [Crossref] [PubMed]
  46. Davies RR, Haldeman S, McCulloch MA, et al. Ventricular assist devices as a bridge-to-transplant improve early post-transplant outcomes in children. J Heart Lung Transplant 2014;33:704-12. [Crossref] [PubMed]
  47. Mathew J, Villa CR, Morales D, et al. Favorable Waitlist and Posttransplant Outcomes in Children and Adolescent Patients Supported With Durable Continuous-Flow Ventricular Assist Devices. Am J Transplant 2016;16:2352-9. [Crossref] [PubMed]
  48. Sutcliffe DL, Pruitt E, Cantor RS, et al. Post-transplant outcomes in pediatric ventricular assist device patients: A PediMACS-Pediatric Heart Transplant Study linkage analysis. J Heart Lung Transplant 2018;37:715-22. [Crossref] [PubMed]
  49. Marcos-Alonso S, Gil N, García-Guereta L, et al. Impact of mechanical circulatory support on survival in pediatric heart transplantation. Pediatr Transplant 2020;24:e13707. [Crossref] [PubMed]
  50. Shi WY, Marasco SF, Saxena P, et al. Outcomes of ventricular assist device implantation in children and young adults: the Melbourne experience. ANZ J Surg 2016;86:996-1001. [Crossref] [PubMed]
  51. Pac M, Kocabeyoglu SS, Kervan U, et al. Third Generation Ventricular Assist Device: Mid-Term Outcomes of the HeartWare HVAD in Pediatric Patients. Artif Organs 2018;42:141-7. [Crossref] [PubMed]
  52. Bryant R 3rd, Rizwan R, Villa CR, et al. Transplant Outcomes for Congenital Heart Disease Patients Bridged With a Ventricular Assist Device. Ann Thorac Surg 2018;106:588-94. [Crossref] [PubMed]
  53. Rossano JW, Singh TP, Cherikh WS, et al. The International Thoracic Organ Transplant Registry of the International Society for Heart and Lung Transplantation: Twenty-second pediatric heart transplantation report - 2019; Focus theme: Donor and recipient size match. J Heart Lung Transplant 2019;38:1028-41. [Crossref] [PubMed]
  54. Bryant R 3rd, Zafar F, Castleberry C, et al. Transplant Survival After Berlin Heart EXCOR Support. ASAIO J 2017;63:80-5. [Crossref] [PubMed]
  55. Jeewa A, Imamura M, Canter C, et al. Long-term outcomes after transplantation after support with a pulsatile pediatric ventricular assist device. J Heart Lung Transplant 2019;38:449-55. [Crossref] [PubMed]
  56. Peng DM, Rosenthal DN, Zafar F, et al. Collaboration and new data in ACTION: a learning health care system to improve pediatric heart failure and ventricular assist device outcomes. Transl Pediatr 2019;8:349-55. [Crossref] [PubMed]
  57. Villa CR, Moore RA, Morales DL, et al. The total artificial heart in pediatrics: outcomes in an evolving field. Ann Cardiothorac Surg 2020;9:104-9. [Crossref] [PubMed]
  58. Spinner JA, Tunuguntla HP, Tume SC, et al. "Compassionate" Cases of the Jarvik 2015 Ventricular Assist Device. ASAIO J 2021;67:1036-43. [Crossref] [PubMed]
  59. Thomas TO, Chandrakasan S, O'Brien M, et al. The use of a Berlin Heart EXCOR LVAD in a child receiving chemotherapy for Castleman's disease. Pediatr Transplant 2015;19:E15-8. [Crossref] [PubMed]
  60. Maat AP, van Thiel RJ, Dalinghaus M, et al. Connecting the Centrimag Levitronix pump to Berlin Heart Excor cannulae; a new approach to bridge to bridge. J Heart Lung Transplant 2008;27:112-5. [Crossref] [PubMed]
  61. Yarlagadda VV, Shin AY, Reinhartz O, et al. The current role of temporary circulatory assist devices in US children awaiting heart transplant. J Heart Lung Transplant 2015;34:S100. [Crossref]
  62. Dimas VV, Morray BH, Kim DW, et al. A multicenter study of the impella device for mechanical support of the systemic circulation in pediatric and adolescent patients. Catheter Cardiovasc Interv 2017;90:124-9. [Crossref] [PubMed]
  63. Seese L, Hickey G, Keebler ME, et al. Direct bridging to cardiac transplantation with the surgically implanted Impella 5.0 device. Clin Transplant 2020;34:e13818. [Crossref] [PubMed]
doi: 10.21037/pm-21-10
Cite this article as: Bearl DW. The importance of mechanical circulatory support on pediatric waitlist and post heart transplant survival: a narrative review. Pediatr Med 2022;5:25.

Download Citation